Tree Diagnosis

Pulling Tests Explained: TreeQinetic and Fakopp Pulling Test

By Isaki Kasahara, a Japanese arborist pruning, assessing and caring for Japan’s trees and gardens · Updated November 28, 2026

A tree pulling test uses a rope and a winch to put a controlled sideways load on a standing tree while sensors record the force in the rope, the tilt at the base of the trunk and the strain in the outer wood. Instruments such as the PiCUS TreeQinetic and the Fakopp Pulling Test keep that load small enough for the tree to spring back, then estimate how much bending the roots and the trunk could withstand and compare it with the bending an assumed wind would cause.

A Healthy Street Tree, Stopped at a Quarter of a Degree — The Tokyo Trial

On a road managed by the Tokyo Metropolitan Government, a rope ran from the trunk of a street tree to a hand-operated wire-rope puller (a chirhoru, チルホール) fixed to the tree next to it. Part-way along the rope hung a TreeQinetic Forcemeter. A strain sensor sat on the part of the trunk where breakage was a concern, in line with the pull; an inclinometer sat at ground level near the root collar, on the side at right angles to the pull. The researchers worked the puller until the base of the trunk had tilted 0.25°, then stopped. That tree was sound, and it stood up again when the load came off.

Brush painting of a street tree on a city footpath with a sling round its trunk below the crown, a steel rope running to a hand-lever puller hooked to the next street tree, a blue load meter part-way along the rope, small blue sensors on the trunk, near its base, traffic cones, two workers standing back
The kind of set-up the Tokyo report describes: rope from a street tree to a wire-rope puller on the next tree, a TreeQinetic Forcemeter part-way along it, an inclinometer near the ground, an elastometer on the trunk. Not a picture of the actual site; instrument shapes follow IML’s product photographs. — Illustration: Isaki Kasahara

Four trees, two kinds of test

Ishii and Yoshioka reported the trial in 2023 in the Landscape Technical Report of the Japanese Institute of Landscape Architecture. Four street trees were tested; the Japanese text names the species enju (エンジュ), and the paper is not consistent about the scientific name, so this article leaves it at “street trees”. One was healthy. The other three were damaged trees already scheduled for felling; their crowns had been removed beforehand, and they were pulled past the peak load.

The result that raised a question

The data went into Arbostat, the analysis program used with TreeQinetic, for the uprooting side of the assessment, with a wind speed of 30 m/s entered as the load to compare against. All four trees, the healthy one included, came out with a safety factor below 1. That does not mean the four were equally likely to fall; it means all four landed in the same band of a calculation.

The authors also ran the simple rule described later in this article, multiplying the moment at 0.25° by 2.5. For the healthy tree, that gave a wind speed of about 43.6 m/s at uprooting, well above the 30 m/s the software had been given. The two routes from the same measurement pointed in opposite directions.

The authors did not conclude that the healthy tree was dangerous. They called for the theory and computation inside the software to be examined, and wrote that how its parameters, which appear to come from the country where the method was developed, should be used in Japan needs study. That is the thread this article follows: what a pulling test measures, what it extrapolates, what it assumes, and which assumptions travel.

Why Pull a Tree at All — Wind Is a Bending Load

Wind presses on the crown, high above the ground, and that pressure acts on the trunk like a hand on the end of a lever. What the roots and the lower trunk feel is a bending moment: a sideways force multiplied by the height at which it acts.

Root plate or trunk

Under that moment a tree can give way in two places. Either the root plate — the mass of roots and soil around the base — rotates out of the ground, which is uprooting, or the trunk breaks somewhere above the base. A single pull loads both at once; the test reads the base and the trunk with separate sensors.

What Japan’s street-tree damage surveys counted

Japan’s National Institute for Land and Infrastructure Management (NILIM) collected reports of street-tree damage — uprooting, stem breakage, leaning, branch loss — between April 2017 and October 2018. Of 9,367 trees in the tally by weather cause, typhoons accounted for 8,578, or 92%; damage was reported on 6,603 trees for Typhoon Jebi (No. 21) of 2018 alone. In the separate tally by type of damage for all causes, uprooting was reported for 961 entries, 10% of 9,389, a total that counts some trees more than once.

A later nationwide survey by the Ministry of Land, Infrastructure, Transport and Tourism (MLIT) put street-tree falls from 2018 to 2022 at about 5,200 a year on average, about 3,700 of them caused by strong winds and other disasters. MLIT’s 2026 guideline lists pulling a tree to grasp its stability among new techniques, partly as a reference when pruning to reduce wind pressure — the subject of how Japan prunes trees against typhoons.

The Set-Up — Rope, Anchor, Winch and Load Cell

The rope replaces the wind. Everything else in the set-up exists to make that substitution measurable: a known force, at a known height, in a known direction.

Diagram of a pulling test seen from the side: a rope from high in a tree runs down to the base of a second tree, with a hand winch, an in-line load cell, a tilt sensor at the root flare, two strain sensors on the trunk
A static pulling test, drawn after the Fakopp Pulling Test manual: rope high in the tree, anchor at the base of another tree, winch, load cell in the line, tilt sensor at the root collar, strain sensors on the trunk. A schematic; sensor positions are illustrative. — Illustration: Isaki Kasahara

Where the rope goes

The Fakopp manual places the rope on the trunk close to the centre of the crown, or on a strong branch near it; the product page puts it between half and two-thirds of the tree’s height. The manual’s layout drawing marks four distances: the rope height on the tree, the height of the crown centre, the horizontal distance to the anchor, and any difference in ground level between the two trees. The product page adds that the anchor should be at least twice as far away as the rope is high, which keeps the rope at a shallow angle.

What the rope is anchored to

Both the Fakopp diagram and the Tokyo trial show a neighbouring tree as the anchor. Published test layouts also show a vehicle’s tow hitch and a ground anchor, and a 51-month study of urban trees by Fini and colleagues fixed a Tirfor to a vehicle “with sufficient mass and soil adherence”. Fakopp lists the pulling device as an option rather than part of the basic set.

A grey hand-operated wire-rope puller with its lever, a coil of steel wire rope beside it on a concrete floor
A Tirfor-type wire-rope puller with its cable. Working the lever draws the rope through the body, letting a test load a tree slowly. — Photo: Bryn Pinzgauer, CC BY 2.0, via Wikimedia Commons

Measuring the force in the line

A load cell sits in the rope between the winch and the tree. TreeQinetic calls its unit the Forcemeter, and IML’s specifications list a built-in angle sensor that records the rope’s angle. With rope tension T, rope angle α from the horizontal and attachment height h, the bending moment at the base is the horizontal component of the pull times the height: T cos α × h. Detter, Rust and Krišāns give this calculation in their 2023 study.

Loading slowly

Fakopp’s instructions are to load the cable slowly and evenly with the winch. The readings show live in the software while the tree is loaded and then released.

Four-panel diagram of a pulling test: a rope rigged from the crown base to an anchor tree; sensors fitted at the trunk base, on the trunk, wired to a yellow central unit with a laptop; a hand winch with a load cell tensioning the rope; a laptop screen showing a rising curve that returns almost along itself
A pulling test in four steps, drawn after the Fakopp manual’s set-up: rig the rope, fit the sensors, pull slowly, read the force–tilt record, which rises with the load, then falls back when it is released. A schematic. — Illustration: Isaki Kasahara

Three Readings — Force, Tilt and Strain

A pulling test records three things together: the force in the rope, the tilt of the trunk base, and the change in length of the outermost wood fibres of the trunk. The first is the load; the other two are the tree’s response.

Two-panel diagram of the same tree pulled to the left: on the left, the whole root plate rotates, a tilt sensor at the base highlighted; on the right, the root plate stays still while the trunk bends, its fibres stretched on one face, compressed on the other, with strain sensors on both faces
What each sensor watches. Left: rotation of the root plate, read by the inclinometer at the root collar. Right: bending of the trunk, which stretches fibres on the side away from the pull, compresses them on the near side, read by elastometers. In a real test both happen at once, on a tiny scale; here they are separated, exaggerated. — Illustration: Isaki Kasahara

The inclinometer at the root collar

The inclinometer is fixed close to the root collar, where the trunk meets the roots. In TreeQinetic it sits on a magnetic holder fixed to the trunk and is levelled there; its housing measures 140 × 60 × 55 mm, its resolution is 0.002° and its stated accuracy 0.005°. Fakopp’s inclinometer, a grey box on a plate screwed to the root collar and levelled with a two-axis levelling head, resolves 0.001°. The fineness is needed because the tilts involved are far too small to read by eye.

Where the root collar looks poor, the Fakopp manual asks for two inclinometers set 90° apart on the collar, kept off damaged wood (on an oval collar, one along each axis). If the two give safety factors more than 50% apart, the measurement is not to be trusted.

The elastometer on the trunk

An elastometer measures how much the distance between two points on the trunk changes under load. TreeQinetic’s elastometer is a blue housing, 220 × 60 × 38 mm, clamped to two pins driven into the wood (the xylem, not just the bark) 200 mm apart. Its range is ±2 mm, with a resolution of 0.1 µm and an accuracy of 1 µm. Fakopp’s elastometer is a slim aluminium bar screwed to the trunk. Divide the change in length by the gauge length and you have the strain of the outermost fibres at that cross-section.

Two-panel close-up of the same bark: on the left a blue elastometer housing held off the bark by a steel pin at each end, no cable; on the right a slim silver aluminium rail fixed by a screw at each end, a black cable leaving its lower end
Two elastometers on the same stretch of trunk. Left: TreeQinetic, a blue housing on two pins in the wood 200 mm apart, sending its readings wirelessly. Right: Fakopp, an aluminium rail screwed to the trunk, cabled to the central unit. Shapes follow the makers’ product photographs; not to scale. — Illustration: Isaki Kasahara

Elastometers go where breakage is a concern, as on the Tokyo tree. Fakopp’s manual adds two constraints: each one faces towards or away from the pull, on the line the cable defines, and none goes higher than half the height at which the cable is attached. Its elasto extension comes with two, and the software gives a breakage result for each elastometer position.

Where the pulling stops

Detter and Rust describe a procedure that limits the base tilt to 0.25°, at which the deformation is fully reversible. The Fakopp manual sets the field alarm for tilt at 0.2°; the capacity of the rope, the load cell and the winch is a further limit. The person at the winch decides when to stop.

The same manual also rules out some days and some trees altogether. No test in rain or at freezing temperatures, and none when gusts exceed 25 km/h, because wind on the crown spoils the fit of the points. No test on a split trunk, or where pulling could open a fork. Loads of up to about 3.2 t can be applied, so the area is closed to the public and the crew, apart from the winch operator, stays at least 2 m from the cable.

From a Small Tilt to Uprooting — The Tipping Curve

The inclinometer data stop at a fraction of a degree, while root plates fail at far larger angles. One way to bridge the gap is a curve.

The generalised tipping curve

In a 2002 paper for the International Society of Arboriculture, Brudi and van Wassenaer described the Elasto-Inclino method and its generalised tipping curve, derived from more than 400 failure tests on trees of different species in different soils, with the initial failure of the root plate between 2.5 and 4 degrees of lean. The curve rises steeply at first, then flattens to a maximum. If a tree’s first fraction of a degree follows the start of the curve, its maximum can be estimated.

Chart diagram: a curve of bending moment against base tilt rises steeply, then flattens into a peak; measured dots lie only in a narrow band near the origin, the rest of the curve dashed, a dashed line marking the peak height
The logic of the uprooting estimate. Points are measured only in the first fraction of a degree (shaded band); the rest of the curve, up to the maximum, is a model estimate. A schematic; no scale implied. — Illustration: Isaki Kasahara

Two ways to extrapolate

Fakopp fits the measured load-and-tilt points to the general uprooting function and converts the predicted maximum load into a bending moment. A simpler rule takes the moment needed to tilt the base by 0.25° and multiplies it by 2.5. TreeQinetic’s data go to Arbostat, which compares the measured tipping curve with typical curves.

Checking the estimate against trees pulled over

Over two decades the method has been checked by pulling trees all the way. Rust and Detter, comparing extrapolations on almost 100 trees pulled to failure in 2019, reported that the Wessolly–Erb method tended to underestimate anchorage strength while another curve equation then in use tended to overestimate it.

In the 2023 study by Detter, Rust and Krišāns, more than 280 trees, with their crowns removed, were measured to 0.25° and then uprooted. The response at 0.25° was strongly related to the strength at failure. In that dataset the fixed 2.5 multiplier tended to underestimate, especially in small trees; the older curve equation tended to overestimate; and a revised equation could not be fitted for some trees. Some small trees reached their maximum resistance at base angles well above 2.5°. These are tendencies in a dataset, not a correction that can be applied to one tree.

From Small Strain to Breakage — The Trunk Side

The elastometer answers the other question: how much more load the trunk could take at the measured cross-section before its outer fibres reach their limit.

Extending a straight line

For wood, strain rises in proportion to load up to a limit. The software takes the measured relationship between strain and load and extends it to the limit for the species. Fakopp’s calculation of the critical load uses the strain at the limit of linear elasticity; Detter and Rust speak of the proportional limit (Proportionalitätsgrenze).

Where the species limits come from

The limit strain comes from tables of wood properties. Brudi and van Wassenaer cite the Stuttgart table of wood strength, which lists modulus of elasticity, longitudinal strength, elastic limit and recommended drag factors by species, and explain the limit strain as the ratio of longitudinal compressive strength to modulus of elasticity (ε = σmax / E). Fakopp’s manual carries a species table in its appendix. The trunk estimate therefore depends on whether the reference strain suits the species and the section measured — the same kind of question the Tokyo authors raised about inputs on the uprooting side.

Hollow trunks

In 2005 Detter, Brudi and Bischoff looked back over more than 4,800 Elasto-Inclino tests in practice and found no critical degree of hollowness that held generally across species, forms and sites. A 2017 analysis by Huang and colleagues showed that thin-walled hollow trunks can fail by flattening of the cross-section — Brazier buckling, tangential cracking, shear — as well as by ordinary bending. When local strain is read through a bending model, the shape of the section and the failure mode assumed both matter.

The Safety Factor — Dividing by an Assumed Wind

The result of a pulling test is a ratio, not a reading. For uprooting, the estimated maximum resisting moment is divided by the corresponding design-wind moment; for breakage, the estimated critical moment at each measured cross-section is divided by the design-wind moment at that section.

Two-panel diagram of the same tree: left, wind pushes on the crown, leaves streaming; right, a rope tied at crown centre height pulls the tree on a calm day; in both a dashed line marks the height of the load above a dot at the base
Why a rope can stand in for wind. The wind spreads over the crown; the rope acts at one point. Both bend the base by a sideways force times a height. The test measures the rope; the wind is calculated. — Illustration: Isaki Kasahara

How the wind is calculated

Brudi and van Wassenaer describe the wind load as estimated from crown area, wind speed, an aerodynamic drag factor and air density, acting at a height to give a bending moment. Arbostat also works with regional wind parameters and terrain categories based on standards. The wind side is calculated separately from the measured rope load, and depends on those inputs, some set by the assessor and some by defaults in the software or the standards.

Reading the number

What the report showsWhat to check
A safety factor for uprootingWhich wind speed, crown area, drag factor were assumed; in which direction the tree was pulled
A safety factor for each elastometerWhich cross-section it applies to; which species values were used
Several values for one treeFakopp’s manual says to use the lowest

Fakopp sorts results into three bands: above 1.5, 1 to 1.5, below 1. At 1 the estimated resistance equals the design-wind moment; at 1.5 it exceeds it by half. Brudi and van Wassenaer give a safety factor of at least 1.5 as the engineering margin. When the Tokyo report put a healthy tree below 1, the useful response was the one its authors gave: look at what went into the number.

TreeQinetic and Fakopp Pulling Test Side by Side

With elastometers fitted, both systems record force, tilt and strain on the same Elasto-Inclino logic. They differ in hardware, connection and software.

PiCUS TreeQinetic

IML took over the business of Rostock-based argus electronic GmbH, maker of the PiCUS instruments, in January 2022; current TreeQinetic documents are in the name of IML Electronic GmbH. The standard set includes the Forcemeter V2, inclinometer, elastometers, a radio relay and software; data are normally sent wirelessly, with a Bluetooth USB stick and cables for wired measurement. The measuring software displays and saves the readings; the analysis is done in Arbostat, a separate program from arbosafe.

Diagram of a TreeQinetic set-up seen from the side: a sling high on the tested tree, a rope with a blue Forcemeter between two shackles running to a hand winch at the base of an anchor tree, two blue elastometers on the trunk, a blue inclinometer at the root collar, a navy radio hub with a laptop on the ground, no cables on the tree
PiCUS TreeQinetic on a tree: the Forcemeter in the rope, the inclinometer at the root collar, elastometers on the trunk, all sending wirelessly to the radio hub, then a laptop. Drawn after IML’s product photographs; sensors enlarged so they can be seen. — Illustration: Isaki Kasahara

Fakopp Pulling Test

Fakopp Kft. is based in Hungary. Its inclino set includes one or two inclinometers with mounts, a central unit, a load cell with display, serial cables and Windows software, with the pulling device optional; the elasto extension adds two elastometers. The inclinometers and elastometers connect to the central unit, and the LineScale load cell can link to the PC by Bluetooth Low Energy or USB. For units manufactured after 1 October 2025, the manual says the elastometer box is integrated into the sensors. The software calculates safety factors for uprooting and breakage itself.

Diagram of the lower trunk of a tested tree: a grey inclinometer with a green panel on a black ball-head mount at the root flare, two slim silver elastometer rails on opposite edges of the trunk, black cables from all three to a yellow central unit on the ground, then on to a laptop on a folding table
The Fakopp Pulling Test at the trunk base: inclinometer on its ball-head mount at the root collar, elastometers on the two faces of the trunk, every sensor cabled to the yellow central unit, which passes the readings to the laptop. Drawn after Fakopp’s product photographs. — Illustration: Isaki Kasahara

The numbers the makers publish

PiCUS TreeQineticFakopp Pulling Test
What a set measuresForce, base tilt, fibre strainForce, base tilt; fibre strain with the elasto extension
InclinometerResolution 0.002°, accuracy 0.005°; range ±15° (product page), ±30° (manual v1.0)Resolution 0.001°; range ±2° (ST-015, product page), ±30° (high-precision model, 2026 manual)
ElastometerPins 200 mm apart; range ±2 mm; resolution 0.1 µm, accuracy 1 µmSpan 250 mm, resolution 0.3 µm (product page); 244 mm, 0.0001 mm (2026 manual)
Load cellForcemeter: range 0–40 kN (product page), 0–60 kN (manual v1.0); resolution 0.01 kNKaliber 5 t, 50 kN working limit; LineScale 3 t, 30 kN (2026 manual)
Data linkWireless as standard; cable possibleSensors cabled to the central unit; LineScale by Bluetooth or USB
AnalysisMeasuring software, then ArbostatPulling Test software

The published figures differ between documents, and the documents do not always say which model each applies to. Neither system is presented here as the better one; they are two hardware routes to the same measurement.

Where Pulling Tests Sit in Japanese Tree Diagnosis

Tokyo’s published procedure starts with the eye and continues with instruments that look inside the trunk. Pulling tests sit beyond both.

Brush painting of a pulling test on a street tree: a sling round the trunk below the crown, a rope along the footpath to the base of the next tree with a winch, a small load cell, an inclinometer at the root collar cabled to a yellow box with a laptop on a stool, cones with a rope barrier closing the footpath, two workers in helmets by the winch
What a pulling test asks of a street: a clear line along the footpath to an anchor, the footpath closed for the duration, room for the winch, the laptop. MLIT’s guideline asks for attention to this working space. — Illustration: Isaki Kasahara

Tokyo’s manual

Tokyo’s 2021 street-tree diagnosis manual makes visual inspection compulsory and sends trees judged to need it on to instrument diagnosis of decay and of the root stock. In the published flow and in the chapter on instrument methods, a static pulling test is not a standard step. For the decay instruments themselves, see resistance drilling and the comparison of decay detection methods.

The 2026 national guideline

MLIT’s 2026 guideline for promoting street-tree inspection lists pulling a tree to grasp its stability as an example of new technology. It presents the results as additional material, on top of conventional inspection, for deciding on measures for trees that are especially worth keeping, and asks for attention to the working space needed and to how the results are interpreted.

Research and training in Japan

Shimada (2018), in the Journal of the Japanese Society of Revegetation Technology, compared five pairs of hinoki cypress in a plantation — normal trees against trees with roots exposed near the base — by measuring maximum resistance moment in tree pulling tests. In 2026 the programme of the Tree Health Research Society’s 16th workshop listed the Pulling Test, PiCUS TreeQinetic and an RT checker for pulling tests on standing trees in the field. Fakopp’s distributor list names FTS.,Ltd. for Japan.

Where static pulling fits in ISA advanced assessment

In the ISA framework, an instrumented static pull is a load test used in Level 3, advanced assessment, as Smiley, Matheny and Lilly set out in 2012; Andreas Detter’s 2023 ISA talk placed it among the methods for advanced assessment of stability and breaking strength. In practice the three settings differ: analysis inputs developed in Europe, a North American framework that names the test as one advanced option, and a Japanese road guideline that treats it as extra material for important trees. How the Japanese and North American systems divide the work more broadly is set out in tree risk assessment in Japan and TRAQ.

What Changes the Result — Soil, Frost, Direction, Size

A pulling test describes one tree, on one day, in one direction. Each of those belongs on the record.

Wet soil

In an irrigation experiment by Detter and colleagues (2019), the tilt under the same load increased by almost 6% after the soil was wetted, with differences between trees. Soil moisture on the test day is part of the result.

Frozen soil

In Peltola and colleagues’ Finnish pulling experiments (2000), all 20 Scots pines pulled in frozen soil broke; in unfrozen conditions, 78 of 95 trees of three species uprooted. The soil condition changed which way the trees failed.

Direction

In a 2025 study by Andreozzi and colleagues comparing the prevailing wind direction with the direction at right angles, the predicted overturning moment was higher in the north direction for 7 of 10 trees. A result belongs to the direction in which it was measured.

Large, sound trees

Sani and colleagues (2012) evaluated over fifty stone pines (Pinus pinea) in Mediterranean cities and found that, in large and presumably healthy trees, getting enough response to apply the generalised tipping curve was a challenge.

Brush painting of a large old camphor tree alone on a park lawn, a sling round its trunk under the crown, a rope with a blue load meter running across the grass to another tree, small blue sensors on the trunk, at its base, a person far off holding a laptop
A large, sound tree under a pulling test, drawn with TreeQinetic instruments. With a heavy trunk, a broad root plate, a load small enough to be safe may tilt the base too little for the tipping curve to be applied. — Illustration: Isaki Kasahara

What to Ask When a Report Says “Below 1”

Which wind?

The safety factor divides by a calculated wind. The wind speed, crown area and drag factor are in the report or the software; read them before the number.

Which failure, which section?

The uprooting value describes the root plate in the direction pulled. Each breakage value describes one cross-section where an elastometer sat. A weakness elsewhere is not measured directly.

Which species values?

The trunk estimate rests on a species limit strain from a table. If the species, or a close relative, is not in the table, the choice of substitute matters.

Was it pulled to failure?

Routine tests stop near 0.25° (or at Fakopp’s 0.2° alarm). Pulling to failure belongs to research, like the three damaged trees in Tokyo and the 280-plus trees of the 2023 study.

Frequently asked questions

What is a tree pulling test?

A static load test in which a winch pulls on a rope tied high in a tree while a load cell, an inclinometer at the root collar and elastometers on the trunk record force, tilt and fibre strain. Software extrapolates resistance to uprooting and breakage and compares it with an assumed wind.

Does a pulling test damage the tree?

The load is limited to keep the response elastic: Detter and Rust describe stopping at 0.25° of base tilt as fully reversible, and Fakopp’s manual sets a tilt alarm at 0.2°. The sling bears on the bark, and the pins of TreeQinetic’s elastometer go into the wood.

What is the difference between TreeQinetic and the Fakopp Pulling Test?

With elastometers fitted, both measure force, base tilt and fibre strain. TreeQinetic (IML, Germany) sends data wirelessly as standard, with analysis in Arbostat; Fakopp’s system (Hungary) cables the sensors to a central unit and calculates safety factors in its own software.

Why 0.25 degrees?

It is a small, recoverable tilt at which the start of the tipping curve can be measured. The resistance is extrapolated from it, either by fitting a generalised tipping curve or by a fixed multiple; both have been checked against trees pulled to failure.

Is the pulling test used in Japan?

It is not a standard step in Tokyo’s 2021 street-tree diagnosis manual. A 2023 study used TreeQinetic on Tokyo street trees, MLIT’s 2026 guideline lists pulling among new techniques for trees worth keeping, and the Tree Health Research Society’s 2026 workshop programme listed both instruments.

Sources

– 石井・吉岡「街路樹の引き倒し試験による倒木可能性の評価基準の検討」『ランドスケープ技術報告集』2, 日本造園学会, 2023, pp. 34–38 — https://www.jstage.jst.go.jp/article/jilatech/2/0/2_34/_pdf/-char/en (accessed 2026-11-24) – IML Electronic, PiCUS TreeQinetic (product page) — https://www.iml-electronic.com/product/picus-treeqinetic/ (accessed 2026-11-24) – IML Electronic, PiCUS TreeQinetic Manual v1.0 — https://www.iml-electronic.com/wp-content/uploads/2024/08/v1.0_PiCUS_TreeQinetic_Manual_EN.pdf (accessed 2026-11-24) – IML Electronic, “argus electronic wird zu IML Electronic”, 2021 — https://www.iml-electronic.de/die-iml-unternehmensgruppe-waechst-argus-electronic-wird-zu-iml-electronic/ (accessed 2026-11-24) – Fakopp Kft., Pulling Test (product page) — https://fakopp.com/en/product/pullingtest/ (accessed 2026-11-24) – Fakopp Kft., Pulling Test Manual, 2026 — https://files.fakopp.com/pullingtest/pullingtest_manual.pdf (accessed 2026-11-24) – Fakopp Kft., Contact page, Japan distributor listing — https://fakopp.com/en/contact/ (accessed 2026-11-24) – arbosafe, Performance range Arbostat 2.0 — https://arbosafe.com/en/technische-details/ ; Windloads — https://arbosafe.com/en/windlasten/ (accessed 2026-11-24) – Brudi, E. & van Wassenaer, P., “Trees and Statics: Non-Destructive Failure Analysis”, ISA, 2002 — https://www.tree-consult.org/upload/mediapool/pdf/baumstatik_und_biomechanik/trees-and-statics-nondestructive-failure-analysis.pdf (accessed 2026-11-24) – Detter, A. & Rust, S., “Aktuelle Untersuchungsergebnisse zu Zugversuchen”, Jahrbuch der Baumpflege, 2013, pp. 87–100 — https://wp.arbosafe.com/wp-content/uploads/2025/05/detter_rust-zugversuche_JdB-2013_S_87_-_100.pdf (accessed 2026-11-24) – Detter, A., Rust, S. & Krišāns, O., “Experimental Test of Non-Destructive Methods to Assess the Anchorage of Trees”, Forests 14(3), 533, 2023 — https://www.mdpi.com/1999-4907/14/3/533 (accessed 2026-11-24) – Rust, S. & Detter, A., “Experimental test of non-destructive methods to assess the anchorage of urban trees”, 21st International Nondestructive Testing and Evaluation of Wood Symposium, 2019 — https://www.tree-consult.org/upload/mediapool/pdf/baumstatik_und_biomechanik/rust_detter-2019-anchorage_ndte.pdf (accessed 2026-11-24) – Detter, A. et al., “Ambient influences on the results of non-destructive pulling tests”, 2019 — https://www.tree-consult.org/upload/mediapool/pdf/baumstatik_und_biomechanik/detter_rust-2019-ambient_influences_final.pdf (accessed 2026-11-24) – Detter, A., Brudi, E. & Bischoff, F., “Statics Integrated Methods: Results from pulling tests in the past decades”, 2005 — https://www.tree-consult.org/upload/mediapool/pdf/baumstatik_und_biomechanik/results-from-pulling-tests-in-the-past-decades.pdf (accessed 2026-11-24) – Huang, Y.-H. et al., “Failure mechanism of hollow tree trunks due to cross-sectional flattening”, Royal Society Open Science, 2017 — https://pmc.ncbi.nlm.nih.gov/articles/PMC5414253/ (accessed 2026-11-24) – Andreozzi, L. et al., “On the Uprooting Stability of Trees: Combined Loading Effect on Tree Stability Assessment”, Forests 16(12), 1780, 2025 — https://www.mdpi.com/1999-4907/16/12/1780 (accessed 2026-11-24) – Peltola, H. et al., “Mechanical stability of Scots pine, Norway spruce and birch: an analysis of tree-pulling experiments in Finland”, Forest Ecology and Management, 2000 — https://www.academia.edu/124148973/Mechanical_stability_of_Scots_pine_Norway_spruce_and_birch_an_analysis_of_tree_pulling_experiments_in_Finland (accessed 2026-11-24) – Sani, L. et al., “Preliminary experiments and verification of controlled pulling tests for tree stability assessments in Mediterranean urban areas”, Biosystems Engineering, 2012 — https://www.academia.edu/96210947/Preliminary_experiments_and_verification_of_controlled_pulling_tests_for_tree_stability_assessments_in_Mediterranean_urban_areas (accessed 2026-11-24) – Fini, A. et al., “Evaluating the effects of trenching on growth, physiology and uprooting resistance of two urban tree species over 51 months”, Urban Forestry & Urban Greening, 2020 — https://www.academia.edu/93228538/Evaluating_the_effects_of_trenching_on_growth_physiology_and_uprooting_resistance_of_two_urban_tree_species_over_51_months (accessed 2026-11-24) – Smiley, E. T., Matheny, N. & Lilly, S., “Tree Risk Assessment: Levels of Assessment”, Arborist News, ISA, 2012 — https://studylib.net/doc/18681954/tree-risk-assessment—international-society-of-arboricul… (accessed 2026-11-24) – Detter, A., “Applied Tree Statics”, ISA, 2023 (transcript) — https://www.isa-arbor.com/Portals/0/Assets/PDF/CR2023_Andreas_Detter_Transcript.pdf (accessed 2026-11-24) – 国土技術政策総合研究所『街路樹の倒伏対策の手引き 第2版』国総研資料第1059号, 2019, 第3編 pp. 3-1–3-8 — https://www.nilim.go.jp/lab/bcg/siryou/tnn/tnn1059pdf/Ks1059014.pdf (accessed 2026-11-24) – 国土交通省「街路樹の倒木に関する全国調査結果について」2023 — https://www.mlit.go.jp/report/press/road01_hh_001729.html (accessed 2026-11-24) – 国土交通省道路局『街路樹点検の実施促進のためのガイドライン』2026, p. 18 — https://www.mlit.go.jp/road/ir/ir-council/gairoju/pdf/r8guideline.pdf (accessed 2026-11-24) – 東京都建設局『令和3年度 街路樹診断等マニュアル』本編 — https://www.kensetsu.metro.tokyo.lg.jp/documents/d/kensetsu/000051876 (accessed 2026-11-24) – 島田「根元付近の根系が露出したヒノキ立木の引き倒し抵抗力」日本緑化工学会誌 44(1), 2018, p. 123 — https://www.jstage.jst.go.jp/article/jjsrt/44/1/44_123/_article/-char/ja (accessed 2026-11-24) – 樹木医学会「第16回樹木医学会ワークショップ」2026 — https://www.thrs.jp/workshop/16th_workshop.html (accessed 2026-11-24)

↑